Node reference
How to use Clip Grid node in Oraphim
Use the Clip Grid node in Oraphim. Learn its purpose, exact inputs, outputs, registered controls, example workflow, troubleshooting, and type ID geometry.grid_clip.
Updated August 28, 2026How to use Clip Grid node in Oraphim
Type ID: geometry.grid_clip
Category: Transform
What this node does
Processes grid, volume, or SDF data with the Clip Grid operation.
The current Oraphim runtime registers 8 sockets and 7 properties for this node. Its main registered inputs are Grid, Min X, Min Y; its main outputs are Grid. The tables below are generated from the runtime registry rather than a handwritten approximation.
Inputs
| Socket | Key | Type |
|---|---|---|
| Grid | grid |
Geometry3D |
| Min X | minX |
Int |
| Min Y | minY |
Int |
| Min Z | minZ |
Int |
| Max X | maxX |
Int |
| Max Y | maxY |
Int |
| Max Z | maxZ |
Int |
Outputs
| Socket | Key | Type |
|---|---|---|
| Grid | out_geometry |
Geometry3D |
Controls
| Control | Key | Type | Group | Registry default |
|---|---|---|---|---|
| Data Type | dataType |
String |
Node | 0.0 |
| Min X | minX |
Int |
Inputs | 0.0 |
| Min Y | minY |
Int |
Inputs | 0.0 |
| Min Z | minZ |
Int |
Inputs | 0.0 |
| Max X | maxX |
Int |
Inputs | 32.0 |
| Max Y | maxY |
Int |
Inputs | 32.0 |
| Max Z | maxZ |
Int |
Inputs | 32.0 |
How to use it
- Add Clip Grid from node search. Use
geometry.grid_clipwhen you need the exact registry entry. - Connect a compatible
Geometry3Dsource to Grid. Add the other inputs only when the operation needs them. - Start with the registry defaults and adjust Data Type, Min X, Min Y first so you can see the node's effect in isolation.
- Route Grid (
Geometry3D) into a compatible downstream node, viewer, or output path. - Preview a representative frame, change one input/control at a time, and save/reopen reusable graphs to verify persistence.
Practical example
Create a small test graph with Clip Grid. Feed a compatible source into Grid. Change Data Type away from its registry default and compare the result. Connect Grid to a compatible downstream stage so the result is visible. Keeping this test graph small makes socket-type, context, and parameter mistakes easier to diagnose before the node is used in a production graph.
Troubleshooting
- If a connection is rejected, compare the exact socket data types in the tables above; Oraphim graph connections are typed.
- If the result looks unchanged, confirm this node is on the active path to the viewer/output and that the expected graph/resource is selected.
- If a control is unavailable, check required inputs and whether the property belongs to an internal or mode-dependent group.
- If a saved graph behaves differently later, reopen it and verify node identity, connections, and edited property values before rendering.
Related nodes
- Bevel Faces —
geometry.bevel_faces - Clone Elements —
geometry.clone_elements - Curve to Points —
geometry.curve_to_points - Duplicate Elements —
geometry.duplicate_elements - Edge Paths to Curves —
geometry.edge_paths_to_curves
Return to the complete Oraphim node reference.