Node reference

How to use Scale Constraint node in Oraphim

Use the Scale Constraint node in Oraphim. Learn its purpose, exact inputs, outputs, registered controls, example workflow, troubleshooting, and type ID motion.constraint.scale.

Updated August 28, 2026

How to use Scale Constraint node in Oraphim

Type ID: motion.constraint.scale
Category: Transform

What this node does

The Scale Constraint node is registered in Oraphim's Transform category and performs the graph operation represented by its sockets and controls below.

The current Oraphim runtime registers 7 sockets and 13 properties for this node. Its main registered inputs are Scale, Target, Offset; its main outputs are Scale, Correction, Valid. The tables below are generated from the runtime registry rather than a handwritten approximation.

Inputs

Socket Key Type
Scale in_scale Vector3
Target in_target Vector3
Offset in_offset Vector3
Weight in_weight Float

Outputs

Socket Key Type
Scale out_scale Vector3
Correction out_correction Vector3
Valid out_valid Bool

Controls

Control Key Type Group Registry default
Weight weight Float Constraint 1.0
Affect X affectX Bool Channels 1.0
Affect Y affectY Bool Channels 1.0
Affect Z affectZ Bool Channels 1.0
Scale X sx Float Source 1.0
Scale Y sy Float Source 1.0
Scale Z sz Float Source 1.0
Target X tx Float Target 1.0
Target Y ty Float Target 1.0
Target Z tz Float Target 1.0
Offset X ox Float Offset 1.0
Offset Y oy Float Offset 1.0
Offset Z oz Float Offset 1.0

How to use it

  1. Add Scale Constraint from node search. Use motion.constraint.scale when you need the exact registry entry.
  2. Connect a compatible Vector3 source to Scale. Add the other inputs only when the operation needs them.
  3. Start with the registry defaults and adjust Weight, Affect X, Affect Y first so you can see the node's effect in isolation.
  4. Route Scale (Vector3) into a compatible downstream node, viewer, or output path.
  5. Preview a representative frame, change one input/control at a time, and save/reopen reusable graphs to verify persistence.

Practical example

Create a small test graph with Scale Constraint. Feed a compatible source into Scale. Change Weight away from its registry default and compare the result. Connect Scale to a compatible downstream stage so the result is visible. Keeping this test graph small makes socket-type, context, and parameter mistakes easier to diagnose before the node is used in a production graph.

Troubleshooting

  • If a connection is rejected, compare the exact socket data types in the tables above; Oraphim graph connections are typed.
  • If the result looks unchanged, confirm this node is on the active path to the viewer/output and that the expected graph/resource is selected.
  • If a control is unavailable, check required inputs and whether the property belongs to an internal or mode-dependent group.
  • If a saved graph behaves differently later, reopen it and verify node identity, connections, and edited property values before rendering.

Return to the complete Oraphim node reference.